BTKNL - OSTEOSCAN - HDP

  • MSDS: BTKNL
  • Manufacturer: MALLINCKRODT DIAGNOSTICS
  • Product Name: OSTEOSCAN - HDP
  • National Stock Number: 6550-00N040065
Product Identification

Product ID:OSTEOSCAN - HDP
MSDS Date:01/01/1993
FSC:6550
NIIN:00N040065
MSDS Number: BTKNL

Responsible Party
MALLINCKRODT DIAGNOSTICS
2703 WAGNER PLACE
MARYLAND HEIGHTS, MO 63043-3421
US

Emergency Phone: 314-344-3800

Info Phone: 314-344-3800

Cage: 2A916

Contractor
MALLINCKRODT DIAGNOSTICS
MARYLAND HEIGHTS, MO 63043-3421 US

Telephone: 314-344-3800

Cage: 2A916

Ingredients

GENTISTIC ACID ETHANOLAMIDE

CAS: 490-79-9

RTECS: LY3850000


STANNOUS CHLORIDE, SOLID

CAS: 7772-99-8

RTECS: XP8700000

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-NOT EXPECTED TO BE A HEALTH
HAZARD. INGESTION-NOT EXPECTED TO BE A HEALTH HAZARD. SKIN-NOT
EXPECTED TO BE A HEALTH HAZARD. EYE-NOT EXPECTED TO BE A HEALTH
HAZARD. CHRONIC: NOT EPECTED TO BE A CHRONIC HEALTH HAZARD.
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:THE HAZARDOUS INGREDIENT FOUND IN OSTEOSCAN-HDP
ARE SKIN AND EYE IRRITANTS, BUT DUE DUE TO THE SMALL QUANTITY
PRESENT IN EACH CONTAINER, NO ADVERSE HEALTH EFFECTS ARE EXPECTED
TO OCCUR FROM EXPOSURE.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

First Aid

First Aid:INHALATION-NOT EXPECTED TO REQUIRE FIRST AID MEASURES.
INGESTION-NOT EXPECTED TO REQUIRE FIRST AID MEASURES. SKIN-WASH
EXPOSED AREAS WITH SOAP & WATER. GET MEDICAL ATTENTION IF
IRRITATION DEVELOPS. EY E-WASH THOROUGHLY WITH RUNNING WATER. GET
MEDICAL ATTENTION IF IRRITATION DEVELOPS.

Fire Fighting

Extinguishing Media:USE ANY MEAN SUITABLE FOR EXTINGUISHING SURROUNDING
FIRE.
Fire Fighting Procedures:IN THE EVENT OF A FIRE, WEAR FULL PROTECTIVE
CLOTHING & NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH
FULL FACEPIECE OPERATED IN PRESSURE DEMAND MODE.
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE AN EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:COLLECT ALL NON-RADIOACTIVE SPILLS AND DISPOSE
OF AS NON-HAZARDOUS WASTE. FOR OSTEOSCAN HDP RECONSTITUTED WITH
SODIUM PERTECHNETATE TC99M: IF ANY LOSS OR RELEASE OF THE
RADIOACTIVE MATERIAL OCCURS, NO TIFY YOUR RADIATION SAFETY
DEPARTMENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT 15C TO 30C PRIOR TO &
FOLLOWING RECONSTITUTION WITH TC-99M AND DISCARD AFTER 8 HOURS FROM
THE TIME OF PREPARATION.
Other Precautions:STORAGE AND DISPOSAL OF PRODUCT SHOULD BE CONTROLLED
IN A MANNER WHICH IS IN COMPLIANCE WITH THE APPROPIATE REGULATIONS
OF THE FEDERAL OR STATE GOVERNMENT AGENCY AUTHORIZED TO LICENSE THE
USE OF THIS RADIONUCLIDE.

Exposure Controls

Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE.
Ventilation:NOT EXPECTED TO REQUIRE ANY SPECIAL VENTILATION.
Protective Gloves:WEAR PROTECTIVE GLOVES.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:CLEAN BODY-COVERING CLOTHING.
Work Hygienic Practices:AS PART OF GOOD LABORATORY & PERSONAL HYGIENE,
& SAFETY PROCEDURE, AVOID ALL UNNECESSARY EXPOSURE TO THIS
CHEMICAL.
Supplemental Safety and Health
ENSURE PROMPT REMOVAL FROM SKIN, EYES AND CLOTHING.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Solubility in Water:SOLUBLE IN WATER.
Appearance and Odor:SMALL, DRY, WHITE CRYSTALS CLINGING INSIDE OF 6 ML
GLASS VIALS.

Stability

Stability Indicator/Materials to Avoid:YES
NO INFORMATION FOUND.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION,
SUBSTANCE MAY EMIT OXIDES OF CARBON & CORROSIVE FUMES OF
HYDROCHLORIC ACID.

Disposal

Waste Disposal Methods:ENSURE COMPLIANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.